The CDT Series Carbon Dioxide and Temperature Transmitters accurately monitor the CO2 concentration and temperature in schools, office buildings, and other indoor environments to help achieve LEED® certification. For increased sensor life, a single-beam dual-wavelength non-dispersive infrared (NDIR) sensor is used to automatically correct the measurement in both occupied and unoccupied buildings against aging effects. The singlebeam dual-wavelength sensor technology provides the highest level of accuracy compared to Automatic Baseline Correction methods which can unintentionally shift the calibration based on CO2 levels and barometric pressure conditions. In order to achieve a higher level of accuracy, the CDT Series includes digital barometric pressure adjustment and the ability to field-calibrate the sensor. Universal outputs allow users to select the transmitter output to be 4 to 20 mA, 0 to 5 VDC, or 0 to 10 VDC to work with virtually any building management controller. An optional relay with user adjustable set points can be used to control exhaust fans, open actuated windows or dampers, or signal a light or horn.

SPECIFICATIONS

Info Sheet  AQ_CDT_CDTR_rev6

Sensor: Single beam, dual-wavelength NDIR.
Range: CO2: 0 to 2000 ; Temperature ; Relative Humidity: 0 to 100%(depending on model)
Temperature: 32 to 122°F (0 to 50°C).
Accuracy: ±40 ppm + 3% of reading.
Temperature Dependence: ±8 ppm / °C at 1100 ppm.
Non-Linearity: 16 ppm.
Pressure Dependence: 0.13% of reading per mm of Hg.
Response Time: 2 minutes for 99% step change.
Ambient Operating Temperature: 0 to 50°C.
Ambient Operating Humidity: 10 to 95% RH (non-condensing).
Power Requirements: 16 to 35 VDC / 19 to 28 VAC.
Power Consumption: Average: 2 watts; Peak: 3.75 watts.
Output:
– Current: 4 to 20 mA (max 500 Ω);
– Voltage: 0 to 5 VDC or 0 to 10 VDC (min 500 Ω);
– Relay: SPST NO 2A @ 30 VDC;

Additional Information

Weight 0.200 kg
Dimensions 160 x 160 x 115 mm
Co2,Temperature, Humidity

Co2 Only, Co2 / Temperature, Co2 / Temperature / Humidity Output 2 Percent

Sensor Output

Universal Outputs, Universal Outputs (Co2 and Rh) Temp 10k Type II

Product Enquiry

Related Products

  • Wall Sensor For Temp, Humidity and Co2

    Temperature and Humidity/Dew Point Sensors – Wall Mount

    $171.79–$210.41 (exc GST)
    Select options
  • Sensor Casing

    Carbon Monoxide Sensor

    $404.51–$715.00 (exc GST)
    Select options
  • Placeholder

    Wall Mount Temperature Sensor

    $16.86–$18.25 (exc GST)
    Select options
  • RHP Duct

    Temperature and Humidity Sensors – Indoor

    $171.10–$264.68 (exc GST)
    Select options

Copyright © 2019 · Log in