Product Description
60 Watt (2.5amp) Industrial DIN Rail Switchmode Power Supplies – 24V
The BAELLUFF BAE0005 power supplies provides a reliable DC power source for any industrial control system. Combining wide operating temperature range (-20~70°C), compact enclosures, industrial standards and approvals, and offering short circuit, over load, over voltage, and over temperature protection, the BAE0005 series makes your power supply choice a simple one.
Down Load Product Sheet
| • Specifications |
General
Net weight 0.2 kg
Efficiency > 90 % (for 230 V AC and nominal values)
Insulation voltage input/output 4 kV AC (type test)
3 kV AC (routine test)
Protection class II (in closed control cabinet)
> 785000 h (40°C)
Mounting position horizontal DIN rail NS 35, EN 60715
Assembly instructions Alignable: 0 mm horizontally, 30 mm vertically
Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC
Low Voltage Directive Conformance with LV directive 2006/95/EC
Standard – Electrical equipment of machines EN 60204-1
Standard – Electrical safety IEC 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations
and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV)
Standard – Safe isolation DIN VDE 0100-410
Standard – Limitation of mains harmonic currents EN 61000-3-2
Approval – requirement of the semiconductor industry with regard to
mains voltage dips EN 61000-4-11
Information technology equipment – safety (CB scheme) CB Scheme
UL approvals UL Listed UL 508
UL/C-UL Recognized UL 60950
NEC Class 2 as per UL 1310
Dimensions
Width 35 mm
Height 90 mm
Depth 84 mm
Ambient conditions
Degree of protection IP20
Ambient temperature (operation) -25 °C … 70 °C (> 55° C derating : 2.5%/K)
Ambient temperature (storage/transport) -40 °C … 85 °C
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
Noise immunity EN 61000-6-2:2005
Input data
Nominal input voltage range 100 V AC … 240 V AC
Input voltage range 85 V AC … 264 V AC
AC frequency range 45 Hz … 65 Hz
Inrush surge current < 30 A (typical)
Power failure bypass > 20 ms (120 V AC)
> 85 ms (230 V AC)
Input fuse 2.5 A (slow-blow, internal)
Choice of suitable fuses 6 A … 16 A (Characteristics B, C, D, K)
Type of protection Transient surge protection
Protective circuit/component Varistor
Output data
Nominal output voltage 24 V DC ±1 %
Nominal output current 2.5 A (-25°C … 55°C)
Derating 55 °C … 70 °C (2.5%/K)
Connection in parallel Yes, for redundancy and increased capacity
Connection in series Yes
Control deviation < 1 % (change in load, static 10 % … 90 %)
< 2 % (Dynamic load change 10 % … 90 %, 10 Hz)
< 0.1 % (change in input voltage ±10 %)
Residual ripple < 30 mVPP (with nominal values)
Output current 2.5 A (-25°C … 55°C)
Output power 60 W
Typical response time < 1 s
Maximum power dissipation NO-Load < 0.3 W
Power loss nominal load max. < 7 W
Approvals
UL Recognized / UL Listed / cUL Recognized / cUL Listed / IECEE CB Scheme / EAC / EAC / cULus Recognized / cULus Listed